Compare Products
Hide
VS
Models
Series
Highlight Features
Hardware Specifications |
RG-CS83-24GT4XS-PD |
RG-CS83-48GT4XS-PD |
Interface Specifications |
||
Fixed ports |
24 x 10/100/1000 BASE-T ports 4 x 1G/10G SFP+ ports PoE standards: IEEE 802.3af and 802.3at |
48 x 10/100/1000 BASE-T ports 4 x 1G/10G SFP+ ports PoE standards: IEEE 802.3af and 802.3at |
Fans modules |
1 x fixed fan module |
1 x fixed fan module |
Power modules |
2 replaceable hot-swappable power supply slots |
2 replaceable hot-swappable power supply slots |
Fixed management ports |
1 x MGMT port, 1 x console port, and 1 x USB port |
1 x MGMT port, 1 x console port, and 1 x USB port |
System Specifications |
||
Packet forwarding rate |
96 Mpps |
132 Mpps |
Switching capacity |
128 Gbps |
176 Gbps |
MAC address table size |
32,000 |
|
ARP table size |
4,000 |
|
Number of IPv4 unicast routes |
8,000 |
|
Number of IPv4 multicast routes |
2,500 |
|
Number of IPv6 unicast routes |
4,000 |
|
Number of IPv6 multicast routes |
1,200 |
|
Number of ACEs |
Ingress: 3,500 Egress:1,500 |
|
Number of VSU members |
4 |
|
VLAN translation |
4,094 |
|
Dimensions and Weight |
||
Dimensions (W x D x H) |
442 x 420 x 43.6 mm (17.40 x 16.54 x 1.72 in), 1 RU |
|
Weight (empty chassis and fan modules) |
4.3 kg (9.48 lbs) |
4.6 kg (10.14 lbs) |
CPU and Storage |
||
CPU |
Dual cores, with the clock speed of 1.2 GHz |
|
Flash memory |
2 GB |
|
BootROM |
16 MB |
|
SDRAM |
1 GB |
|
Data packet buffer |
3 MB |
|
Power and Consumption |
||
Maximum power consumption |
< 65 W (non-PoE) < 810 W (PoE full load) |
< 75 W (non-PoE) < 1570 W (PoE full load) |
Maximum output power |
RG-PA600I-P-F: 600 W (PoE: 370 W) RG-PA1000I-P-F: 176 V AC to 290 V AC, 1000W 90 V AC to 176 V AC, 930 W (PoE: 740 W) |
|
Rated input voltage |
RG-PA600I-P-F: AC: 100 V AC to 240 V AC, 50/60 Hz HVDC: 240 V DC RG-PA1000I-P-F: AC: 100 V AC to 240 V AC, 50/60 Hz HVDC: 240 V DC |
|
Maximum input voltage |
RG-PA600I-P-F: AC: 90 V AC to 264 V AC, 47/63 Hz HVDC: 192 V DC to 288 V DC RG-PA1000I-P-F: AC: 90 V AC to 264 V AC, 47/63 Hz HVDC: 192 V DC to 288 V DC |
|
Environment and Reliability |
||
MTBF |
≥ 356,000 hours (dual power modules) ≥ 208,000 hours (single power module) |
≥ 315,000 hours (dual power modules) ≥ 193,000 hours (single power module) |
Primary Airflow |
Left-to-right and front-to-right airflow |
|
Operating temperature |
0°C to 45°C (32°F to 113°F) |
|
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
|
Operating humidity |
10% to 90% RH (non-condensing) |
|
Storage humidity |
5% to 95% RH (non-condensing) |
|
Operating noise |
27°C: 51.6 dB 45°C: 57.4 dB |
27°C: 51.6 dB 45°C: 58.3 dB |
Interface surge protection |
Power port: 6 kV/6 kV Telecom port: 10 kV (MGMT port: 4 kV) |
Power port: 6 kV/6 kV Telecom port: 10 kV (MGMT port: 4 kV) |
RG-CS83-PD Series |
|
Feature |
Description |
Ethernet switching |
Jumbo frame (maximum length: 9216 bytes) |
IEEE 802.1Q (4K VLANs) |
|
Voice VLAN |
|
Super VLAN and private VLAN |
|
MAC VLAN, port-based VLAN, protocol-based VLAN, and IP-subnet based VLAN |
|
GVRP |
|
Basic QinQ Selective QinQ |
|
STP, RSTP, and MSTP |
|
ERPS (G.8032) |
|
LLDP/LLDP-MED |
|
LACP (IEEE 802.3ad) |
|
IP service |
ARP |
DHCP client, DHCP relay, and DHCP server |
|
DHCP snooping |
|
DNS |
|
DHCPv6 client and DHCPv6 relay |
|
DHCPv6 snooping |
|
Neighbor Discovery (ND) and ND snooping |
|
IP routing |
Static routing |
RIP, RIPng |
|
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6 |
|
BGP4 and BGP4+ |
|
IPv4 and IPv6 VRF |
|
IPv4 and IPv6 PBR |
|
Multicast |
IGMP v1/v2/v3, and IGMP proxy |
IGMP v1/v2/v3 snooping |
|
PIM-DM, PIM-SM, and PIM-SSM |
|
MSDP |
|
MLD v1/v2 |
|
MLD snooping v1/v2 |
|
PIM-SMv6, PIM-SSM v6 |
|
ACL and QoS |
Standard IP ACLs Extended IP ACLs Extended MAC ACLs ACL80 IPv6 ACL |
ACL redirection |
|
Port traffic identification |
|
Port traffic rate limiting |
|
802.1p/DSCP/ToS traffic classification Eight priority queues per interface |
|
Traffic policing: CAR |
|
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ |
|
Congestion avoidance: tail drop, RED, and WRED |
|
Rate limiting in each queue |
|
Security |
Multiple AAA modes |
RADIUS and TACAS+ |
|
Port-based and MAC-based 802.1x authentication |
|
Web authentication |
|
Allowlist |
|
HTTPS |
|
SSHv1, SSHv2 |
|
Global IP-MAC binding |
|
ICMP |
|
Port isolation and port security |
|
IP Source Guard |
|
SAVI |
|
Gateway ARP anti-spoofing |
|
CPP(CPU Protection Policy) |
|
NFPP( Network Foundation Protection Policy) |
|
Strict and loose RPF uRPF ignoring default routes |
|
Reliability |
REUP, RLDP, DLDP |
IPv4 VRRP v2/v3 and IPv6 VRRP |
|
BFD |
|
Link tracing, fault notification, and remote loopback based on 802.3ah (EFM) |
|
Hot swapping of power modules and cables |
|
3-level fan speed adjustment Fan fault alarm |
|
Device virtualization |
Virtual Switching Unit (VSU) |
NMS and maintenance |
SPAN, RSPAN, and ERSPAN |
sFlow |
|
NTP and SNTP |
|
FTP and TFTP |
|
SNMP v1/v2/v3 |
|
RMON (1, 2, 3, 9) |
|
NETCONF |
|
CWMP (TR-069) standard protocol |
|
gRPC |
|
Cloud and SON |
|
PoE |
IEEE 802.3af and 802.3at Uninterruptible power supply upon hot start Port priority |
Model |
Description |
RG-CS83-24GT4XS-PD |
24 x 10/100/1000M adaptive electrical ports, 4 x 1G/10G SFP+ ports, supporting PoE remote power supply and the maximum PoE output power of 740 W. (Purchase at least one RG-PA600I-P-F/RG-PA1000I-P-F module.) |
RG-CS83-48GT4XS-PD |
48 x 10/100/1000M adaptive electrical ports, 4 x 1G/10G SFP+ ports, supporting PoE remote power supply and the maximum PoE output power of 1480 W. (Purchase at least one RG-PA600I-P-F/RG-PA1000I-P-F module.) |
RG-PA600I-P-F |
600 W AC power module, PoE power module |
RG-PA1000I-P-F |
1000 W AC power module, PoE power module |
Mini-GBIC-GT |
1000BASE-GT mini GBIC module |
Mini-GBIC-SX-MM850 |
Single-port 1000BASE-SX mini GBIC module (LC interface) |
Mini-GBIC-LX-SM1310 |
Single-port 1000BASE-LX mini GBIC module (LC interface) |
Mini-GBIC-LH40-SM1310 |
Single-port 1000BASE-LH mini GBIC module (LC interface), supporting a transmission distance of 40 km |
Mini-GBIC-ZX100-SM1550 |
1000BASE-ZX mini GBIC module, supporting a transmission distance of 100 km |
XG-SFP-SR-MM850 |
10G LC interface module (62.5/125 μm: 33 m; 50/125 μm: 66 m; 300-meter transmission at modal bandwidth of 2000 MHz•km), applicable to SFP+ ports |
XG-SFP-LR-SM1310 |
10G LC interface module (1310 nm), 10 km, applicable to SFP+ ports |
XG-SFP-ER-SM1550 |
10G LC interface module (1550 nm), 40 km, applicable to SFP+ ports |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Bize Ulaşın
How can we help you?
Your opinions and feelings are crucial for our improvement.
Fill in the survey