Compare Products

Hide

Clear All

VS

RG-S6980-64QC Anahtarlar - 1
RG-S6980-64QC Anahtarlar - 2
RG-S6980-64QC Anahtarlar - 3
RG-S6980-64QC Anahtarlar - 4
RG-S6980-64QC Anahtarlar - 5
RG-S6980-64QC Anahtarlar - 6
RG-S6980-64QC Anahtarlar - 7
RG-S6980-64QC Anahtarlar - 8
RG-S6980-64QC Anahtarlar - 9
RG-S6980-64QC Anahtarlar - 10
RG-S6980-64QC Anahtarlar - 1
RG-S6980-64QC Anahtarlar - 2
RG-S6980-64QC Anahtarlar - 3
RG-S6980-64QC Anahtarlar - 4
RG-S6980-64QC Anahtarlar - 5
RG-S6980-64QC Anahtarlar - 6
RG-S6980-64QC Anahtarlar - 7
RG-S6980-64QC Anahtarlar - 8
RG-S6980-64QC Anahtarlar - 9
RG-S6980-64QC Anahtarlar - 10
Picture

RG-S6980-64QC – 64-Port 400GE Data Center Core Switch, 4 RU

High-density 400GE Fixed Switch with 400GE ZR/ZR+ Optical Modules, Supporting Long-Distance Interconnection 

Models
Highlight Features
  • High-density 400GE switch with 64 x 400GE QSFP-DD ports in the 4-RU space

  • Hardware-level redundancy, ensuring service continuity

  • 400GE QSFP-DD ports, interconnection at the distance of up to 120 km, and smooth and rapid data communication

  • Lossless Ethernet, ensuring zero packet loss during RDMA E2E communication

  • Telemetry-based network monitoring and automated O&M, making management simple and efficient

Sales Enquiry
Features
 

Data Center 400GE Core Switch RG-S6980-64QC

High-speed and high-density core switch in a data center with 64 x 400GE QSFP-DD ports in the 4 RU space, delivering scalable,
high-performance and high-bandwidth services and coping with interconnection on a large data center network

Ports

Dimensions

IPv4/IPv6 Host Routing Entries
1000K/640K

Buffer
113.66MB

Hardware-level Redundancy, Ensuring Service Continuity

Hot-Swappable Redundant Power Modules

Hot-Swappable Redundant Fan Modules

Power modules in 2+2 redundancy mode, failover in seconds, and power module replacement without network interruption, providing double protection for links

Communication at the Maximum Distance of 120 km and Easy DCI

400GE ZR/ZR+ optical modules are used for interconnection reducing intermediate transmission devices and helping a cloud or hyper-scale
data center network to adapt to growing high-bandwidth services.

Lossless Ethernet with RDMA E2E Communication
and Zero Packet Loss

With RDMA technology, data does not need to be handled by the CPU during device communication. This reduces the CPU burden
and effectively solves the network latency problem.
PFC+ECN, intelligent data exchange, and packet loss prevention, ensuring lossless data transmission

Telemetry-based Network Monitoring and Automated O&M,
Making Management Simple and Efficient

The switch enabled with telemetry provides clear data status and hierarchy.
The switch uses the push mode to proactively collect and push information and to provide sub-second-level network monitoring in real time,
making network management more efficient and accurate.

Specifications

Hardware Specifications

System Specifications

RG-S6980-64QC

Ports

64 × 400GE ports (QSFP-DD), up to 128 x 200GE ports

Expansion Module Slots

Not supported

Expansion Modules

Four power supply module slots

Eight fan module slots

Management Port

One management port, one console port, and one USB port, compliant with the USB2.0 standard

Switching Capacity

51.2 Tbps

Packet Forwarding Rate

10,300 Mpps

802.1Q VLAN

4,094

Dimensions and Weight

Dimensions (W × D × H)

442 mm x 760 mm x 175 mm (17.40 in. x 29.92 in. x 6.89 in., 4 RU)

Weight

38 kg (83.78 lbs., including eight fan modules and four power supply modules)

Power Supply and Consumption

Power Consumption

● Max: 2,400 W

● Typical: 1,760 W

● Static: 500 W

AC

AC input:

Rated voltage range: 100 V AC to 127 V AC

Frequency: 50 Hz to 60 Hz

Maximum rated input current: 13.8 A

Rated voltage range: 200 V AC to 240 V AC

Frequency: 50 Hz to 60 Hz

Maximum rated input current: 8.5 A

High-Voltage DC

HVDC input: 180 V DC to 300 V DC

Rated voltage: 240 V DC

Rated input current: 6.5 A

Environment and Reliability

Operating Temperature

0ºC to 40ºC (32ºF to 104ºF)

Storage Temperature

–40 °C to +70 °C (–40 °F to +158 °F)

Operating Humidity

10% RH to 90% RH (Non-condensing)

Storage Humidity

5% to 95% RH (non-condensing)

Altitude

Operating altitude: up to 5,000 m (16,404.20 ft.)

Storage altitude: up to 5,000 m (16,404.20 ft.)

 

Software Specifications

Software Specifications

RG-S6980-64QC

Layer 2 Protocols

IEEE 802.3ae (10GBase), IEEE 802.3ak, IEEE 802.3an, IEEE 802.3x, IEEE 802.3ad (Link Aggregation Control Protocol), IEEE 802.1p, IEEE 802.1Q, IEEE 802.1D (STP), IEEE 802.1w (RSTP), IEEE 802.1s (MSTP), jumbo frame (9 KB)

Layer 3 Protocols (IPv4)

BGP4, OSPFv2, RIPv1, RIPv2, LPM routing, PBR, routing policy, ECMP, WCMP, VRRP

IPv6 Protocols

Neighbor discovery, ICMPv6, path MTU discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, IPv6 QoS

IPv6 Features

Static routing, ECMP, PBR, OSPFv3, RIPng, BGP4+

Data Center Features

PFC, ECN

RDMA

VXLAN, BGP-EVPN

PFC deadlock prevention

* AI ECN

* ECN overlay

RALB, AILB

Visualization

gRPC

sFlow

QoS

802.1p, DSCP, and ToS mapping
ACL-based traffic classification
Priority marking/remarking
Multiple queue scheduling mechanisms, including SP, WRR, WFQ, DRR, SP+WRR, SP+WFQ, and SP+DRR
Congestion avoidance mechanisms such as WRED and tail discarding

Hgh Availability Design

GR for RIP/OSPF/BGP, BFD, DLDP, REUP dual-link fast switching, RLDP unidirectional link detection, 2+2 power redundancy and fan redundancy, and hot swappable line cards and power modules

Security Features

Network Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, cleartext and MD5-based authentication for OSPF, RIPv2, and BGPv4 packets, Telnet login from specified IP addresses, broadcast packet suppression, hierarchical user management

Management Mode

SNMP v1/v2c/v3, telnet, console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, ZTP, NETCONF, Python, fan and power alarm, and overheat alarm

Other Protocols

DHCP client, DHCP relay, DHCP server, DNS client, proxy ARP, and Syslog


Safety and Regulatory Compliance

Specification

RG-S6980-64QC

Safety

● IEC 62368-1

● EN 62368-1

● BS EN 62368-1

● GB 4943.1

Electromagnetic Compatibility (EMC)

● EN 55032

● EN 55035

● EN 61000-3-2

● EN 61000-3-3

● BS EN55032

● BS EN 55035

● BS EN 61000-3-2

● BS EN 61000-3-3

● EN 300 386

● GB/T 9254.1

Environment

● 2011/65/EU EN 50581

● 2012/19/EU EN 50419

● (EC) No.1907/2006

● GB/T 26572

*For more country-specific regulatory information and approvals, contact your local sales agency.

Show More
Resources All Resources
Learn about Products or Solutions
Software and Configuration
Order Information

Chassis, Fan Modules, and Power Modules

Model

Description

RG-S6980-64QC

64 x 400GE ports, four power supply module slots, eight fan slots

RG-PA1200I-F

Hot swappable power module, 2+2 redundancy, and front-to-rear airflow

M2EFAN II-F

Hot swappable fan module, 7+1 redundancy, and front-to-rear airflow

 

400GBASE Series Optical Transceivers

Model

Description

400G-QDD-SR8-MM850

400G SR8 transceiver, QSFP-DD form factor, MPO-16 APC, 850 nm, 100 m (328.08 ft.) over MMF

400G-QDD-FR4-SM1310

400G FR4 transceiver, QSFP-DD form factor, Duplex

LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

400G-QDD-DR4-SM1310

400G DR4 transceiver, QSFP-DD form factor, MPO-12 APC, 1310 nm, 500 m (1,640.42 ft.) over SMF

*400G-QDD-ZR-SM1550

400G ZR transceiver, QSFP-DD form factor, LC, tunable wavelength, P2P distance of up to 80 km (262,467.19 ft.) over SMF

* in Ordering Information indicates that the product will be available in the future.

 

100GBASE Series Optical Transceivers

Model

Description

100G-QSFP-iLR4-SM1310

100G iLR4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF

100G-QSFP-LR4-SM1310

100G LR4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF

100G-QSFP-SR-MM850

100G SR transceiver, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF

100G-QSFP-ER4-SM1310

100G ER4 transceiver, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF

100G-AOC-5M

100G AOC cable, QSFP28 form factor, 5 m (16.40 ft.)

100G-AOC-10M

100G AOC cable, QSFP28 form factor, 10 m (32.81 ft.)

Show More
Tips: Product information and performance will be affected by upgrade iteration, specific environment and other factors, so FAQ content is for reference only. For further information, please contact online support.
How would you rate your experience on this page?
Very disatisfying
Very satisfying
If you would like to offer more comment, please type in the textbox below, that would be helpful for the improvement of this page.
Submit
Thank you for your feedback!

Ruijie Networks websites use cookies to deliver and improve the website experience.

See our cookie policy for further details on how we use cookies and how to change your cookie settings.

Cookie Manager

When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.

  • Performance cookies

    Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.

  • Essential cookies

    This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.

Accept All

View Cookie Policy Details

Bize Ulaşın

Bize Ulaşın

How can we help you?

Bize Ulaşın

Get an Order help

Bize Ulaşın

Get a tech support

2024 Ruijie Networks Brand Awareness Survey

Your opinions and feelings are crucial for our improvement.

Fill in the survey